Burn-in and acceptance

Every cluster passes NVIDIA's hardware validation tests, HW-1 to HW-5, before we hand it over. You receive the results in an acceptance report.

GPU burn-in testing is how we check a cluster under load before you run anything on it. Every 1Legion cluster passes NVIDIA's hardware validation for inference providers, tests HW-1 to HW-5, before handover, and the results come to you in an acceptance report. It takes the place of a trial: you get evidence from the hardware you will actually run.

The five burn-in tests

The burn-in is five tests, each aimed at a different part of the cluster, and we hand a cluster over only when it passes all five.

  1. HW-1

    Collective throughput

    NCCL throughput at baseline with nccl-tests, with SHARP-accelerated collectives where the fabric supports them.

    nccl-tests

  2. HW-2

    Every network rail

    Every InfiniBand or RoCE rail tested with ib_write_bw.

    ib_write_bw

  3. HW-3

    GPUDirect and storage

    GPUDirect RDMA and storage smoke tests, including NVMe read and write.

    GPUDirect RDMA, NVMe

  4. HW-4

    NVLink and NVSwitch

    NVLink and NVSwitch link count and bandwidth checked with nvbandwidth.

    nvbandwidth

  5. HW-5

    24-hour soak

    A 24-hour soak under a representative inference load at a sustained power cap.

    inference load at a power cap

Together they cover the paths a distributed workload depends on: between GPUs inside a server (HW-4), between servers across the fabric (HW-1 and HW-2), the network path into GPU memory and the storage path (HW-3), and the whole cluster under sustained load (HW-5). The tests are part of section 15 of our delivery specification.

What each test proves

Each test checks one part of the hardware, and a pass tells you something specific about the cluster you will run.

HW-1: NCCL throughput

NCCL, the NVIDIA Collective Communications Library, is the software GPUs use to exchange data during distributed training and inference, in operations such as all-reduce. HW-1 runs nccl-tests, NVIDIA's benchmark for NCCL, across the cluster, with SHARP where the switches support it. SHARP performs part of each reduction inside the switches, so less data has to cross the network.

A pass shows that GPUs in different servers exchange data at the throughput the test requires. When collective throughput falls short, every step of a distributed job waits on the network.

HW-2: every fabric rail

In a rail-optimized fabric, a rail is the set of links that connects the GPUs in one position, in every server, to their own switches. HW-2 runs ib_write_bw, which measures RDMA write bandwidth between two ports, on every InfiniBand or RoCE rail in the cluster.

A pass shows that each rail performs on its own, not only the fabric on average. That matters because a collective operation runs at the speed of its slowest link: one weak cable, transceiver or port can slow every GPU in a job.

HW-3: GPUDirect RDMA and storage

GPUDirect RDMA lets a network card read and write GPU memory directly, without copying data through the CPU and system memory. HW-3 runs smoke tests, short checks that a path works end to end, on GPUDirect RDMA and on storage, including NVMe read and write.

A pass shows that data reaches the GPUs by the direct path the cluster was designed for, and that the storage path reads and writes. Without GPUDirect RDMA, traffic falls back to a slower route through host memory, and jobs still run, only slower, which is why the path is tested on its own.

Inside each HGX server, the eight GPUs connect to each other through NVLink and NVSwitch, a much faster path than the network between servers. HW-4 uses nvbandwidth, an NVIDIA tool, to measure the bandwidth of those links, and checks the link count: that every link that should be up is up.

A pass shows that every GPU has all of its NVLink links up and that they carry the bandwidth the test expects. A missing link does not stop a server from working; it makes it slower, which is why the count is checked.

HW-5: 24-hour soak

HW-5 runs a representative inference load on the cluster for 24 hours at a sustained power cap, a set power limit held for the whole test. Faults that a short test misses, such as heat-related errors, power problems and intermittent failures, tend to appear over hours of steady load.

A pass shows that the hardware stays stable through a full day of steady, representative load.

The acceptance report

The results of the burn-in come to you in an acceptance report, so you have the evidence when the cluster becomes yours.

The report records the results of HW-1 to HW-5 for your cluster. Keep it as your baseline. The tools are public (nccl-tests, ib_write_bw and nvbandwidth), so if you suspect a problem later, your engineers can run the same tests and compare.

The hardware itself is recorded in our authoritative inventory: every rack, node, GPU, NIC, drive, switch, port, transceiver and cable, with a machine-readable export for you. After handover, the cluster runs under our written operating commitments.

When a node fails

A node that fails a test does not enter service: it is quarantined, repaired or replaced, and tested again.

  1. Quarantine

    The node is taken out of the cluster, so it cannot affect the other nodes or the results.

  2. Repair or replace

    We find and fix the fault, or replace the failed part or the whole node.

  3. Retest

    The repaired or replacement node is tested again, and the cluster is handed over once it passes.

The same discipline continues after handover. We quarantine fatal GPU faults (XID 79, XID 48, double-bit ECC errors and row remapping failures) immediately, and we hold any node suspected of silent data corruption in quarantine.

Why burn-in replaces a trial

We do not offer trials, demos, proofs of concept or short-term rentals; what we offer instead is evidence from the hardware you will actually run.

A trial shows how one server behaves for a short time, usually not the server you will end up with. Our contracts run 36, 48 or 60 months for whole servers, so what you need to know is how the cluster you receive performs. Burn-in tests that on your own hardware, and the acceptance report puts the results in writing.

Before you sign, the delivery specification tells you what you are buying, and our engineers can answer questions about it. Our how to buy page walks through the contract steps from request to handover.

Questions buyers ask

What is GPU burn-in testing?

Running new GPU servers under sustained load before they go into service, so hardware faults show up before your workloads do. Our burn-in is NVIDIA's hardware validation for inference providers, tests HW-1 to HW-5.

Can we run a trial or proof of concept first?

No. We do not offer trials, demos, proofs of concept or short-term rentals. Every cluster passes HW-1 to HW-5 before handover, and you receive the results in an acceptance report.

What is an NCCL test?

A run of nccl-tests, NVIDIA's benchmark for the NCCL library, which measures how fast GPUs exchange data in collective operations such as all-reduce. It is test HW-1 of our burn-in.

Which tools do the tests use?

nccl-tests with SHARP where supported (HW-1), ib_write_bw on every InfiniBand or RoCE rail (HW-2), GPUDirect RDMA and storage smoke tests including NVMe read and write (HW-3), nvbandwidth for NVLink and NVSwitch (HW-4), and a 24-hour soak under representative inference load (HW-5).

What happens if a node fails a test?

The node is quarantined, repaired or replaced, and retested. We hand the cluster over once it passes.

Tell us what you need to run.

Share the hardware, the number of servers, the term and the start date. You receive a written proposal built on our delivery specification.