Space and power, or servers: we add customers and operations

Track A: you have space and power, and we bring hardware, customers and operations. Track B: you have hardware, and we bring colocation, 24/7 operations, remote hands, monitoring and customers.

1Legion's GPU colocation and operations program has two tracks. In Track A, you have data center space and power, and we bring hardware, customers and operations. In Track B, you have hardware or are becoming a GPU cloud provider, and we bring colocation space in our partner facilities, 24/7 operations, remote hands, monitoring and customers.

Choose your track

Choose the track by what you already have: a site with power, or hardware that needs a site, operations and customers.

Track A: you have space and power

For data center owners and operators. We bring hardware, customers from our pipeline and operations. Your facility must meet our partner requirements, summarized on this page.

Track B: you have hardware

For hardware owners and companies becoming GPU cloud providers. We bring colocation space in our partner facilities, 24/7 operations, remote hands, monitoring and customers, under your brand or ours.

Track B is how a company can become a GPU cloud provider without building its own facility or operations team: you bring the hardware and, if you want, the brand, and we run the neocloud operations behind it. If you own or finance GPU servers as an investment rather than to run a cloud, operate your cluster is the closer fit.

What an AI cluster needs from your data center

The key number is the contractual maximum kW per rack, because we plan each HGX B300 GPU node at about 14 kW.

Planning figures from our HGX B300 delivery specification
ItemPlanning power
HGX B300 GPU nodeAbout 14 kW, working assumption
CPU node1.0 kW
Control plane node0.5 kW
Storage node1.3 kW
Network5 percent of GPU load

With those figures, the reference clusters in our delivery specification come to the estimated IT loads below.

Reference configurations from 1Legion's HGX B300 delivery specification. Larger by design.
Item64 nodes128 nodes288 nodes
GPU nodes (8 GPUs each)64128288
GPUs5121,0242,304
CPU nodes2448108
Control plane nodes666
Storage, appliance option (usable)512 TB1,024 TB2,304 TB
Storage, storage-node option9 nodes17 nodes38 nodes
Estimated IT loadabout 0.98 MWabout 1.95 MWabout 4.39 MW

We deploy HGX B300 air cooled today, on the OEM's recommendation at cluster scale. For GB300 NVL72 and later platforms, we need a path to direct-to-chip liquid cooling.

What we ask of a facility

Before we place a cluster, a facility must meet the public summary of our data center partner requirements (1LG-DC-REQ-2026-001 Rev 2), shown with evidence rather than claims.

AreaWhat we ask for
PowerA contractual maximum kW per rack; dual A and B power paths to every rack; concurrent maintainability on power and cooling; generator and UPS autonomy
CoolingAir cooling for HGX B300 today; a path to direct-to-chip liquid cooling for GB300 NVL72 and later
EvidenceTier III design documentation, Uptime Institute certification stated precisely, TIA-942, EN 50600, SOC 2 and ISO 27001, with reference numbers, releasable under NDA
SpaceContiguous space in a private cage or a dedicated hall
Staffing24/7 on-site staffing in place before go-live; remote hands within 30 minutes
Incidents and maintenanceFacility incident notice within 15 minutes, then hourly updates; 14 days' notice of risky maintenance
ConnectivityAt least two independent carriers with 100 Gb/s circuits, physically diverse paths, BGP support, DDoS options, IPv6 and an out-of-band network
TelemetryPower per rack and per feed, cooling, thermal and leak detection, with 12 months of alarm history
Commercial4 to 5 year terms aligned to the customer contract; a ramp that follows contract execution and hardware delivery; expansion rights; a right of first refusal on adjacent space

The data center partner requirements summary is on our downloads page, so you can check your site before a first call.

Facility figures next to our customer commitments

What we ask of the facilityWhat we commit to our customers
Remote hands within 30 minutesFacility engineering or remote hands engaged within 45 minutes, at any hour
Incident notice within 15 minutes, then hourly updatesIncident acknowledged within 15 minutes, updates at least every 60 minutes
14 days' notice of risky maintenanceAt least 7 days' notice of high-risk maintenance
12 months of alarm history12 months of incident and state history

The full list is on our operating commitments page.

How the commercial side works

Colocation is resold per kW on multi-year terms, and operations are paid as a share of rental revenue, a fixed fee or a mix, agreed per partner.

Track A: your facility

We ask for terms of 4 to 5 years aligned to the customer contract. The ramp follows contract execution and hardware delivery, and we ask for expansion rights and a right of first refusal on adjacent space.

Track B: your hardware

Colocation in our partner facilities is resold per kW on multi-year terms. Operations, meaning 24/7 operations, remote hands and monitoring, are agreed per partner as a share of rental revenue, a fixed operating fee or a mix. The service, including customers from our pipeline, can run under your brand or ours.

Every price comes in a written proposal. We do not publish colocation or operating rates.

What each side brings

Each track divides the work between you and us as follows.

Track A: you have space and powerTrack B: you have hardware
SuitsData center owners and operatorsHardware owners and companies becoming GPU cloud providers
You bringSpace, power, cooling, connectivity and 24/7 on-site staff that meet our partner requirementsGPU servers you own or plan to buy, and your brand if you want to use it
1Legion bringsHardware, customers from our pipeline and operationsColocation in our partner facilities, 24/7 operations, remote hands, monitoring and customers
Commercial basis4 to 5 year terms aligned to the customer contractColocation per kW on multi-year terms; operations by revenue share, fee or a mix
To start, sendSite location, power available in MW, contractual kW per rack, cooling and ready-for-service dateGPU model, number of servers and where the hardware is today

How a partnership starts

Five steps take a site or a set of servers from a first message to customers in production.

  1. Send the basics

    Track A: site location, power available in MW, contractual kW per rack, cooling and ready-for-service date. Track B: GPU model, number of servers and where the hardware is today.

  2. First call

    We go through the site or the hardware, the track that fits and the commercial model.

  3. Evidence

    For a site, you share the evidence behind our partner requirements under NDA, from Tier III design documentation to SOC 2 and ISO 27001 reference numbers.

  4. Written agreement

    We agree terms in writing: facility terms of 4 to 5 years for Track A, or colocation per kW and an operations model for Track B.

  5. Deployment and customers

    We rack and burn in the hardware, run it 24/7 and bring customers from our pipeline.

Talk to the partnerships team

Send the basics about your site or your hardware, and we will arrange a first call. If you bring hardware rather than a site, choose that partner type in the form.

Add your country and phone

We do not take customers whose ultimate parent is headquartered in China, Hong Kong, Macau, Russia or an embargoed jurisdiction. How we screen customers

We use these details only to reply to your request.

Questions partners ask

What rack density do you need?

We plan each air-cooled HGX B300 GPU node at about 14 kW, so the contractual maximum kW per rack decides how many nodes each rack holds. It is the key number for us.

Do you need liquid cooling?

Not for HGX B300, which we deploy air cooled today. For GB300 NVL72 and later platforms, we need a path to direct-to-chip liquid cooling.

What evidence do you ask a facility for?

Evidence, not claims: Tier III design documentation, Uptime Institute certification stated precisely, TIA-942, EN 50600, SOC 2 and ISO 27001, with reference numbers, releasable under NDA.

How is colocation priced?

Per kW, on multi-year terms, in a written proposal. We do not publish rates.

Can we sell under our own brand?

Yes, on Track B. We provide colocation, 24/7 operations, remote hands, monitoring and customers, under your brand or ours.

What term do you sign with a facility?

4 to 5 years, aligned to the customer contract, with a ramp that follows contract execution and hardware delivery, expansion rights and a right of first refusal on adjacent space.

Send us your site or your hardware

Start with power, rack density, cooling and a ready-for-service date, or the servers you own.