GPU clusters for AI training

Dedicated NVIDIA HGX B300 clusters with 270 GB of HBM3e and 800 Gb/s of fabric per GPU, built to a published specification and burned in before your first training step.

A 1Legion GPU cluster for AI training is a set of whole NVIDIA HGX B300 servers on an east-west fabric that carries only your traffic, rented to one customer for 36, 48 or 60 months. We build each cluster to our published delivery specification and burn it in before handover, so the first step of a multi-week run starts on nodes that have already passed a 24-hour soak.

What LLM training infrastructure has to sustain

A training run that lasts weeks needs memory for its optimizer state, a fabric with no slow link, fast checkpoint storage and an environment that does not change underneath it.

Memory for optimizer state

Mixed-precision training with the Adam optimizer holds about 16 bytes per parameter in weights, gradients and optimizer state. For a 70B-parameter model that is about 1.1 TB before activations, which fits in the 2.1 TB of HBM3e on one HGX B300 server.

A fabric with no slow link

Sharded and data-parallel training synchronizes gradients across every GPU at every step, so one congested link slows the whole cluster. Our HGX B300 fabrics are fully non-blocking at 800 Gb/s per GPU.

Checkpoint throughput

A checkpoint with FP32 master weights and Adam state for a 70B-parameter model is about 840 GB, and a synchronous save holds every GPU until it is written. Storage is sized per GPU, and checkpoints leave the cluster without egress fees.

An environment that holds still

No other tenant shares your servers or your fabric. Changes on our side follow written change management, with at least 7 days' notice of high-risk maintenance.

Our article on training bottlenecks explains why memory and interconnect, not GPU count, set training throughput.

Which servers fit training workloads

HGX B300 is our main training platform and HGX B200 also has allocation open, while GB300 NVL72 and Vera Rubin are available by reservation.

8-GPU serverHGX B300HGX B200
GPU memory per server2.1 TB HBM3e1,440 GB HBM3e
Memory bandwidth per GPU7.7 TB/s7.7 TB/s
NVLink1.8 TB/s per GPU, 14.4 TB/s total1.8 TB/s per GPU, 14.4 TB/s total
FP4 Tensor per server, sparse and dense144 and 108 PFLOPS144 and 72 PFLOPS
FP8 Tensor per server, sparse72 PFLOPS72 PFLOPS
FP64 per server10 TFLOPS296 TFLOPS

Choose HGX B300 when memory per GPU decides how you shard: 270 GB holds the 140 GB of BF16 weights of a 70B-parameter model on one GPU with 130 GB to spare. Choose HGX B200 when your work mixes training with FP64 simulation. GB300 NVL72 joins 72 Blackwell Ultra GPUs and 36 Grace CPUs in one liquid-cooled NVLink domain with 20 TB of HBM3e and 130 TB/s of NVLink bandwidth. Vera Rubin is the next NVIDIA platform we have on order, with 288 GB of HBM4 per GPU and sixth-generation NVLink.

A dedicated, non-blocking fabric

Every HGX B300 cluster gets its own east-west fabric, rail optimized and fully non-blocking, with 800 Gb/s per GPU.

  • Bandwidth: 1 x 800 or 2 x 400 Gb/s planes per GPU, 6.4 Tb/s per server, with NVIDIA ConnectX-8 preferred.
  • Switching: NVIDIA Spectrum-X or Broadcom Tomahawk 6 preferred, NVIDIA Quantum InfiniBand or Tomahawk 5 accepted.
  • Inside each server: fifth-generation NVLink at 1.8 TB/s per GPU.
  • Storage and services: a separate north-south network at 400 Gb/s per node preferred, RoCEv2 capable, MTU 9000, with no oversubscription on storage leaves.
A rail-optimized east-west fabric, dedicated to one customer

Clusters come in three reference sizes, and larger clusters follow the same design.

Reference configurations from 1Legion's HGX B300 delivery specification. Larger by design.
Item64 nodes128 nodes288 nodes
GPU nodes (8 GPUs each)64128288
GPUs5121,0242,304
CPU nodes2448108
Control plane nodes666
Storage, appliance option (usable)512 TB1,024 TB2,304 TB
Storage, storage-node option9 nodes17 nodes38 nodes
Estimated IT loadabout 0.98 MWabout 1.95 MWabout 4.39 MW

Each size includes CPU nodes for serving, routing and batch work, with at least 6 hardware threads and 24 GB of memory per GPU in the cluster, and six control plane nodes spread over two racks. Our GPU clusters page covers power planning at about 14 kW per GPU node.

Checkpoint and dataset storage

Storage comes in two options, both sized per GPU, and each GPU node adds at least 9.2 TB of raw local NVMe for dataset shards and checkpoint staging.

Option A: a managed appliance

A VAST Data, WEKA or DDN appliance, as you prefer, with at least 1 TB usable per GPU (512 TB on a 64-node cluster), committed throughput and latency per tier, visible usage and quotas, tested recovery and 24/7 vendor escalation.

Option B: storage nodes for your own software

Storage nodes with at least 3 TB raw per GPU on 30.72 TB NVMe PCIe 5.0 drives, from a minimum of 9 nodes, with self-encrypting drives supported. Both options are described on storage and networking.

How we handle faults during a run

When hardware fails mid-run, we take the node out of service and repair or replace it, so your job can restart on healthy nodes.

  • Fatal GPU faults (XID 79, XID 48, double-bit ECC errors and row remapping failures) put a node in quarantine immediately.
  • Recurring XID 13 and XID 31 errors are handled after a count agreed with you.
  • NCCL hangs are correlated with fabric events, so a stalled job is matched to the link behind it.
  • Nodes suspected of silent data corruption stay in quarantine.
  • NVMe drives are replaced before they reach their endurance limits.
15 min Incident acknowledged and an incident commander assigned
60 min Longest interval between incident updates
45 min Facility engineering or remote hands engaged, at any hour
7 days Written postmortem after a customer-impacting incident

Operational telemetry is kept for at least 30 days, and incident and state history for at least 12 months. The full list is in our operating commitments, and our article on why long training runs fail on shared cloud covers the failure modes.

Burn-in instead of a trial

Every cluster passes NVIDIA's hardware validation tests HW-1 to HW-5 before handover, and the results go into your acceptance report.

  1. HW-1

    Collective throughput

    NCCL throughput at baseline with nccl-tests, with SHARP-accelerated collectives where the fabric supports them.

    nccl-tests

  2. HW-2

    Every network rail

    Every InfiniBand or RoCE rail tested with ib_write_bw.

    ib_write_bw

  3. HW-3

    GPUDirect and storage

    GPUDirect RDMA and storage smoke tests, including NVMe read and write.

    GPUDirect RDMA, NVMe

  4. HW-4

    NVLink and NVSwitch

    NVLink and NVSwitch link count and bandwidth checked with nvbandwidth.

    nvbandwidth

  5. HW-5

    24-hour soak

    A 24-hour soak under a representative inference load at a sustained power cap.

    inference load at a power cap

We do not offer trials, proofs of concept or short-term rentals. The acceptance report shows NCCL throughput, every InfiniBand or RoCE rail, NVLink and NVSwitch links and a 24-hour soak, measured on the nodes you will train on. See how burn-in and acceptance works.

Rent GPUs for model training on 36 to 60 month terms

Training clusters are rented as whole servers for 36, 48 or 60 months at one fixed monthly rate, and longer terms carry lower rates.

  1. Request a quote

    Tell us the model size, the number of servers, the term, the site and when you need them.

  2. Proposal

    We send a written proposal against our delivery specification, with each change you need listed as a numbered deviation.

  3. Onboarding and contract

    The company that will run the servers completes our three onboarding forms, signs the rental agreement and pays the down payment.

  4. Build, burn-in and handover

    We build and burn in the cluster in Toronto, or in Delaware as that site comes online, then hand it over with the acceptance report, a shared Slack channel and a named technical account owner.

The balance is billed monthly over the term with no egress fees, and larger allocations may need a bank guarantee or letter of credit. If you want us to run the platform layer, we install and operate managed Kubernetes with the NVIDIA GPU Operator and Network Operator, or managed Slurm. Our article on sustained training on dedicated B300 shows how labs plan a campaign around a fixed term.

Questions buyers ask

What is the smallest training cluster you rent?

We rent whole servers, so the smallest unit is one 8-GPU HGX B300 server on a 36-month term. Our reference clusters are 64, 128 and 288 nodes on one dedicated fabric, and larger clusters follow the same design.

Can we test the cluster before we sign?

We do not offer trials or proofs of concept. Every cluster passes NVIDIA's HW-1 to HW-5 hardware validation tests before handover, and you receive the results in an acceptance report. See burn-in and acceptance.

Do you build InfiniBand or Ethernet training fabrics?

Our delivery specification prefers NVIDIA Spectrum-X or Broadcom Tomahawk 6 and accepts NVIDIA Quantum InfiniBand or Tomahawk 5. Either way the fabric is rail optimized, fully non-blocking, 800 Gb/s per GPU and dedicated to you.

Which storage should we choose for checkpoints?

Option A is a VAST Data, WEKA or DDN appliance with at least 1 TB usable per GPU and 24/7 vendor escalation. Option B is storage nodes with at least 3 TB raw per GPU for storage software you run yourself.

What happens when a GPU fails during a run?

Fatal faults such as XID 79 or double-bit ECC errors put the node in quarantine immediately, and we repair or replace it before it rejoins your cluster. An incident commander is assigned within 15 minutes.

Do you offer one or two year terms for training clusters?

No. GPU servers are rented for 36, 48 or 60 months, and longer terms carry lower rates.

Plan your next training cluster

Tell us the model, the cluster size, the term and the site, and we reply with a written proposal against our delivery specification.