Data centers
GPU servers in service in Toronto and Montreal, HGX B300 capacity coming online in Delaware, a site in development in Finland, and a partner network of data centers across North America, Europe, Africa and Australia.
Our GPU data centers are in Toronto and Montreal, with HGX B300 capacity coming online in Delaware and a site in development in Finland. Around them, our partner network gives us data centers across North America, Europe, Africa and Australia. We name each location by city, and before we place a cluster we ask the facility to meet a written set of requirements for power, cooling, evidence, staffing and connectivity.
Our network
Our own servers run in Toronto and Montreal today. HGX B300 capacity is coming online in Delaware, and our site in Finland is in development. Beyond them, our partner network lets us place dedicated servers and clusters close to your users, or inside the country your data has to stay in. Capacity at each partner site is confirmed in your proposal.
- Data centers
- 49
- Cities
- 26
- Countries
- 12
- Continents
- 4
- Power
- 313+ MW
- In service
- Coming online
- In development
- Partner data center
North America10 locations
-
TorontoCanada
In service
5 data centersTier III100% renewable energy
NVIDIA HGX B300 servers and clusters.
Across the Greater Toronto Area, carrier-neutral.
-
MontrealCanada
In service
8 data centersOver 30 MWHydroelectric power
RTX PRO 6000 Blackwell and other inference servers, with onsite engineering support.
2N power, N+1 cooling and carrier-neutral dark fiber.
-
DelawareUnited States
Coming online
4 data centers22 MW
HGX B300 capacity for customers who need their compute in the United States.
Connected by a private fiber ring, with no Delaware sales tax on colocation.
-
CalgaryCanada
3 data centersTier III100% renewable energy
Western Canada, carrier-neutral.
-
VancouverCanada
3 data centers100% renewable energy
On the Pacific coast, carrier-neutral.
-
ChicagoUnited States
9 MW
West of downtown, directly connected to Chicago's telecommunications hub.
-
DallasUnited States
2 MW
Access to 56 networks, a hub for the South Central United States.
-
Los AngelesUnited States
22 MW
Downtown, connected to 16 major providers through 5 independent entry points.
-
New YorkUnited States
48 MW
A campus just outside New York City, built for hyperscale, with direct access to major carrier networks and cloud on-ramps.
-
SeattleUnited States
3 MW
Connected to global internet exchanges and tier-1 carriers.
Europe16 locations
-
HelsinkiFinland
In development
A brownfield data center site in development for future capacity in Europe.
-
CopenhagenDenmark
3.3 MWTier III100% renewable energy
Serving the Nordics, carrier-neutral.
-
ParisFrance
3.8 MWTier III100% renewable energy
Close to major cloud on-ramps, carrier-neutral.
-
FrankfurtGermany
10 MW100% green power
In one of Europe's largest data center hubs, connected to the DE-CIX internet exchange.
-
MilanItaly
3.2 MWTier III100% renewable energy
Italy's main data center market, carrier-neutral.
-
AmsterdamNetherlands
3 data centers22.8 MW
Access to 26 internet exchanges, including AMS-IX.
-
LisbonPortugal
1.5 MWTier III100% renewable energy
Portugal's main digital hub, on the routes between Europe and Latin America, carrier-neutral.
-
MadridSpain
3 data centers24.7 MW100% renewable energy
The largest European site in the network by power, carrier-neutral, with routes to Latin America.
-
BarcelonaSpain
2 data centers10.5 MWTier III100% renewable energy
Two interconnected facilities run as one platform, carrier-neutral.
-
MálagaSpain
2.8 MWTier III100% renewable energy
Close to the cable routes to Africa and across the Atlantic, carrier-neutral.
-
SevilleSpain
1 MWTier III100% renewable energy
Serving Andalusia, carrier-neutral.
-
ValenciaSpain
0.6 MWTier III100% renewable energy
Close to compute users on the Mediterranean coast.
-
CeutaSpain
0.7 MWTier III
At the gateway between Europe and Africa.
-
ZürichSwitzerland
5.8 MWTier III100% renewable energy
For teams with strict data sovereignty needs.
-
LondonUnited Kingdom
3.8 MWTier III
Central London, with carrier-dense connectivity.
-
LeedsUnited Kingdom
2.8 MWTier III100% renewable energy
The North of England, carrier-neutral.
Australia1 location
-
SydneyAustralia
80 MW
The largest site in the network by power, with 215,000 sq ft of raised floor.
What is served where
Each location has a defined role, so the hardware you need points to the site.
Toronto: HGX B300 colocation
Toronto is in service and hosts NVIDIA HGX B300 capacity, in carrier-neutral colocation. Each HGX B300 server has 8 GPUs with 270 GB of HBM3e per GPU, and clusters are built to our delivery specification. A carrier-neutral facility can connect to many network carriers, which an edge built on two independent transit providers needs. See our NVIDIA HGX B300 servers.
Montreal: GPU servers for inference
Montreal is in service and hosts NVIDIA RTX PRO 6000 Blackwell servers, with 8 GPUs of 96 GB GDDR7 each, and other inference servers, with onsite engineering support. Onsite support means hands-on work on the servers is done by engineers at the site. See our RTX PRO 6000 Blackwell servers and GPU servers for AI inference.
Delaware: HGX B300 in the United States
HGX B300 capacity in Delaware is coming online, for customers who want their HGX B300 servers in the United States. Our Delaware data centers are connected by a private fiber ring. HGX B300 proposals for Toronto and Delaware start from the same delivery specification. Ask us about timing when you request a proposal.
Helsinki: future capacity in Europe
A brownfield data center site in Finland, on previously developed land, is in development for future European capacity.
The partner network
In the other cities of the network we deploy dedicated servers and clusters on request. Before we place a cluster, the facility is checked against the requirements below, and your proposal confirms the hardware, the site and the timing.
For servers marked On request in our catalog, ask us which locations apply. Our GPU servers page shows the status of each model.
How we choose facilities
Before we place a cluster, we ask the facility to meet our data center partner requirements, document 1LG-DC-REQ-2026-001 Rev 2.
| Area | What we ask for |
|---|---|
| Power | A contractual maximum kW per rack; dual A and B power paths to every rack; concurrent maintainability on power and cooling; generator and UPS autonomy |
| Cooling | Air cooling for HGX B300 today; a path to direct-to-chip liquid cooling for GB300 NVL72 and later |
| Evidence | Tier III design documentation, Uptime Institute certification stated precisely, TIA-942, EN 50600, SOC 2 and ISO 27001, with reference numbers, releasable under NDA |
| Space and staffing | Contiguous space in a private cage or dedicated hall; 24/7 on-site staffing in place before go-live; remote hands within 30 minutes |
| Incidents and maintenance | Facility incident notice within 15 minutes and hourly updates; 14 days' notice of risky maintenance |
| Connectivity | At least two independent carriers with 100 Gb/s circuits, physically diverse paths, BGP support, DDoS options, IPv6 and an out-of-band network |
| Telemetry | Power per rack and feed, cooling, thermal and leak detection, with 12 months of alarm history |
| Commercial | 4 to 5 year terms aligned to the customer contract; a ramp that follows contract execution and hardware delivery; expansion rights and a right of first refusal on adjacent space |
- The kW per rack is the key number. At our working assumption of about 14 kW per HGX B300 node, the contractual maximum per rack decides how many nodes each rack can hold.
- Concurrent maintainability means any power or cooling component can be taken out for maintenance without shutting down the racks it serves.
- Response and notice. We ask facilities for remote hands within 30 minutes, incident notice within 15 minutes and 14 days' notice of risky maintenance. Our own commitments to you are facility engineering or remote hands within 45 minutes, incidents acknowledged within 15 minutes, and at least 7 calendar days' notice of high-risk, non-emergency maintenance. See our operating commitments.
- Connectivity. We ask for at least two independent carriers with 100 Gb/s circuits on physically diverse paths because our edge design uses two independent transit providers at 100 Gb/s per circuit, with eBGP failover within a minute.
- Terms aligned with yours. Facility terms of 4 to 5 years are aligned to the customer contract, and expansion rights with a right of first refusal on adjacent space let a cluster grow where it stands.
The evidence row is covered in more detail on our security and compliance page. If you operate a facility that meets these requirements, see colocation and operations.
Air cooling today, liquid cooling next
Our HGX B300 nodes are air cooled today, and we ask facilities for a path to direct-to-chip liquid cooling for GB300 NVL72 and later systems.
HGX B300 nodes are air cooled on the OEM's recommendation at cluster scale. GB300 NVL72 is a rack-scale system of 72 GPUs, and it is liquid cooled: with direct-to-chip cooling, coolant runs through cold plates on the processors and carries the heat out of the rack.
We ask for the path to direct-to-chip cooling now, so the facilities we choose for HGX B300 have a way to host GB300 NVL72 and Vera Rubin systems later. Both are available by reservation.
Why we name cities, not facilities
We name each location by city. We do not publish which facility hosts which cluster.
The city tells you what matters for planning: latency to your users, the jurisdiction the hardware sits in, and where your data is stored. Publishing the building would add little to that, and would tell everyone else where the hardware is. If your due diligence needs more than the city, tell us what you need to see.
For our Canadian locations, see GPU cloud in Canada.
Questions buyers ask
Where are your GPU data centers?
Toronto and Montreal, in Canada, are in service. HGX B300 capacity in Delaware, in the United States, is coming online, and a site in Finland is in development. Our partner network adds data centers in more cities across North America, Europe, Africa and Australia, all listed on this page.
Where are HGX B300 clusters hosted?
In Toronto today, and in Delaware, in the United States, as that capacity comes online. In the other cities of our partner network we deploy on request, and your proposal names the site.
Do you support liquid cooling?
HGX B300 nodes are air cooled, on the OEM's recommendation at cluster scale. We ask facilities for a path to direct-to-chip liquid cooling for GB300 NVL72 and later systems, which are available by reservation.
Why don't you name your facilities?
We name locations by city only. The city is what matters for latency, jurisdiction and data location, and we do not publish where the hardware sits beyond that.
Can we place our own hardware in your data centers?
Yes. If you own hardware or are becoming a cloud provider, we provide colocation space in our partner facilities, with 24/7 operations, remote hands and monitoring. See colocation and operations.
Tell us what you need to run.
Share the hardware, the number of servers, the term and the start date. You receive a written proposal built on our delivery specification.