Our HGX B300 delivery specification

Every HGX B300 proposal we write starts from one document, 1LG-DEL-SPEC-2026-001. This is its public edition: what each cluster includes, what we prefer, and how a change for you is recorded.

This is the public edition of our HGX B300 cluster specification, document 1LG-DEL-SPEC-2026-001, dated September 24, 2026. It is the baseline for every HGX B300 proposal we write: the reference cluster sizes, the nodes, storage and networks, and the operating commitments that come with the cluster. Anything that differs for your cluster appears in your proposal as a numbered deviation.

How the specification works

The specification sets a baseline, and your proposal records every change from it as a numbered deviation. Each item in the document is either Required or Preferred. On this page, minimums are written as "at least" or "minimum", and preferred options are marked "preferred".

Required

Part of the baseline for every HGX B300 proposal. If your cluster needs something different, the change is listed in your proposal as a numbered deviation.

Preferred

The option we prefer where the document allows more than one, such as NVIDIA ConnectX-8 for the backend network cards.

Numbered deviation

A customer-specific change, written into your proposal with its own number, so your engineers and procurement team can check each difference from this baseline before you sign.

Reference cluster sizes

The specification defines three reference clusters, of 64, 128 and 288 GPU nodes, and each size includes the CPU nodes, control plane and storage that go with it.

Reference configurations from 1Legion's HGX B300 delivery specification. Larger by design.
Item64 nodes128 nodes288 nodes
GPU nodes (8 GPUs each)64128288
GPUs5121,0242,304
CPU nodes2448108
Control plane nodes666
Storage, appliance option (usable)512 TB1,024 TB2,304 TB
Storage, storage-node option9 nodes17 nodes38 nodes
Estimated IT loadabout 0.98 MWabout 1.95 MWabout 4.39 MW

Every reference size has six control plane nodes, and the specification sets the control plane at 6 nodes per 2,304 GPUs. The two storage rows correspond to the two storage options described below: usable capacity for an appliance, or a node count for storage nodes.

Planning power

The estimated IT load is built from these planning figures:

ItemPlanning figure
GPU nodeAbout 14 kW (working assumption)
CPU node1.0 kW
Control plane node0.5 kW
Storage node1.3 kW
Network5 percent of GPU load

For the 64-node size, that is 64 GPU nodes at about 14 kW each, plus 24 CPU nodes, 6 control plane nodes, 9 storage nodes and network at 5 percent of GPU load: about 0.98 MW. We plan facility power from these figures, and the contractual maximum kW per rack is the key number we ask of a facility. Our data centers page lists the rest of what we ask.

Compute nodes

Besides storage, a cluster has three kinds of node: GPU nodes that run your workloads, CPU nodes for the services around them, and a control plane that runs the cluster itself.

GPU node

GPU node, from 1LG-DEL-SPEC-2026-001.
ItemSpecification
PlatformNVIDIA HGX B300, 8 GPUs
GPU memory270 GB HBM3e per GPU, 2.1 TB per node, as NVIDIA lists the HGX B300
CoolingAir cooled, on the OEM's recommendation at cluster scale
CPUAt least 128 vCPUs
System memory3 TB preferred; at least 240 GB per GPU (1.92 TB)
Boot drives2 x 1 TB NVMe, mirrored (preferred)
Local data storageAt least 9.2 TB raw NVMe, more than 4 x GPU memory
Backend NIC800 Gb/s per GPU, as 1 x 800, 2 x 400 or 4 x 200 Gb/s; NVIDIA ConnectX-8 preferred
Frontend NICNVIDIA BlueField-3; 2 x 400 Gb/s preferred, 2 x 200 Gb/s minimum
  • Memory. At 270 GB of HBM3e per GPU, each node holds 2.1 TB of GPU memory. System memory of at least 240 GB per GPU gives the host room to stage data and model weights for the GPUs.
  • Local storage. Raw NVMe of at least four times the node's GPU memory keeps datasets, checkpoints and model files next to the GPUs.
  • Network cards. The backend NIC gives each GPU 800 Gb/s into the east-west fabric, in one of three port layouts. The BlueField-3 frontend NIC connects the node to the north-south network.
  • Cooling. The nodes are air cooled because the OEM recommends air at cluster scale.

CPU nodes

ItemSpecification
RoleServices around the GPUs: serving, routing, batch
SizingAt least 6 hardware threads and 24 GB of memory per GPU in the cluster
Processorx86, at least 128 vCPUs, base clock above 3 GHz
Preferred CPUAMD EPYC 9565 or 9575F
Memory4 GB per thread
Frontend NICNVIDIA BlueField-3

CPU nodes run the work around the GPUs, such as serving, routing and batch jobs, so GPU nodes are not tied up with it. Because they are sized per GPU, they grow with the cluster: 512 GPUs need at least 3,072 hardware threads, which is what 24 nodes of 128 vCPUs provide.

Control plane

ItemSpecification
Nodes6 per 2,304 GPUs, spread over two racks
Processor32 vCPUs above 3.65 GHz; AMD EPYC 9175F preferred
Memory128 GB

The control plane runs the cluster's management services. Its six nodes are spread over two racks, so no single rack holds all of them.

Storage

You choose one of two storage designs: a vendor-managed appliance (option A) or storage nodes for your own storage software (option B).

Option A: applianceOption B: storage nodes
What it isA vendor-managed appliance from VAST Data, WEKA or DDN, the vendor you preferStorage nodes for your own storage software
CapacityAt least 1 TB usable per GPUAt least 3 TB raw per GPU
DrivesVendor-supported design30.72 TB NVMe PCIe 5.0; self-encrypting drives supported
At the reference sizes512, 1,024 or 2,304 TB usable9, 17 or 38 nodes, with a minimum of 9

With option A, the appliance service in the specification includes a vendor-supported design with 24/7 escalation, committed throughput and latency per tier, visible usage and quotas, and tested recovery. Option B suits teams that already run their own storage software and want raw capacity under it.

Cluster and edge networks

Every cluster has its own east-west fabric for traffic between GPUs and its own north-south network, and at the edge it gets redundant transit, DDoS scrubbing, NAT and dedicated public addresses.

East-west fabric

ItemSpecification
TopologyRail-optimized, fully non-blocking
Bandwidth per GPU1 x 800 or 2 x 400 Gb/s planes
Switching, preferredNVIDIA Spectrum-X or Broadcom Tomahawk 6
Switching, acceptedNVIDIA Quantum InfiniBand or Broadcom Tomahawk 5
TenancyDedicated to one customer

Rail-optimized means the GPU in each position of every node connects to its own set of switches, its rail, which keeps the paths between matching GPUs short. Fully non-blocking means the fabric can carry every GPU's full bandwidth at the same time, with no oversubscription between switch layers.

A rail-optimized east-west fabric: each GPU position in every node has its own rail of switches.

North-south network

ItemSpecification
Bandwidth per node400 Gb/s preferred, 200 Gb/s minimum
Storage leavesNo oversubscription
GPU leavesOversubscription below 4:1
TransportRoCEv2 capable
MTU9000
TenancyDedicated

Oversubscription is the ratio between the bandwidth a leaf switch offers its nodes and the bandwidth of its uplinks. Storage leaves have none, so reads and checkpoint writes are not held back by the uplinks, and GPU leaves stay below 4:1. RoCEv2 carries RDMA over this Ethernet network, and an MTU of 9000 (jumbo frames) cuts per-packet overhead on large transfers.

Edge and internet services

ItemSpecification
TransitTwo independent providers at 100 Gb/s per circuit, on physically diverse paths
RoutingeBGP with BFD; failover within a minute
Edge routersTwo, redundant, on A and B power
Edge ACLsSet to your rules; changes within one business day
DDoS protectionVolumetric layer 3 and 4 scrubbing from an established provider, activated through BGP within 5 minutes, at least 1 Tb/s
NAT and egressRedundant HA pair, at least 10 million concurrent sessions, dedicated SNAT addresses (typically four)
Public service addressesDedicated (typically eight); you can advertise VIPs over BGP; failover within 5 seconds; IPv6 dual stack
Your IP space and ASNThe edge can advertise your prefixes and your ASN; RPKI ROAs honored; BGP session authentication
Network telemetryNetFlow v9 or IPFIX from both edge routers to your collector
  • Transit and routing. Two independent providers on physically diverse paths mean that one cut cable or one provider's outage is not a single point of failure. BFD detects a failed link quickly, and eBGP fails over to the other provider within a minute.
  • Edge routers. Two redundant routers on A and B power, so the edge does not depend on one router or one power feed.
  • Edge ACLs. The access control lists at the edge follow your rules, and we make changes within one business day.
  • DDoS protection. Volumetric attacks at layers 3 and 4 are diverted through BGP to an established scrubbing provider. Scrubbing is activated within 5 minutes, with at least 1 Tb/s of capacity.
  • NAT and egress. Outbound traffic leaves through a redundant pair that holds at least 10 million concurrent sessions, from SNAT addresses only you use, so partners can allow-list your traffic.
  • Public service addresses. Typically eight dedicated addresses for your services. You can advertise virtual IPs over BGP, failover happens within 5 seconds, and IPv6 runs dual stack.
  • Your IP space and ASN. If you hold your own prefixes and ASN, the edge can advertise them. We honor your RPKI route origin authorizations (ROAs), which tell other networks which ASN may originate your prefixes, and BGP sessions are authenticated.
  • Network telemetry. Both edge routers send NetFlow v9 or IPFIX flow records to your collector, so you see your own traffic.

Operations after handover

The specification also covers what happens around handover: a burn-in before it, and written operating commitments after it.

Before handover, every cluster passes NVIDIA's hardware validation for inference providers, tests HW-1 to HW-5, and the results come to you in an acceptance report. Our burn-in and acceptance page explains what each test proves.

After handover, section 15 of the specification sets out how we run the cluster, starting with these commitments:

CommitmentFigure
Incident acknowledged and an incident commander assignedWithin 15 minutes
Updates while an incident is openAt least every 60 minutes
Network operations engaged, at any hourWithin 15 minutes
Facility engineering or remote hands engagedWithin 45 minutes
Written postmortem after a customer-impacting incidentWithin 7 days
Notice before high-risk planned maintenanceAt least 7 days

The full list, including the inventory, change management and hardware fault handling, is on our operating commitments page. Out-of-band hardware telemetry comes from the BMC through Redfish, with network and facility telemetry where available. Operational telemetry is kept for at least 30 days, and incident and state history for at least 12 months.

Download the specification

Questions buyers ask

What is 1LG-DEL-SPEC-2026-001?

It is 1Legion's HGX B300 delivery specification, dated September 24, 2026, and the baseline for every HGX B300 proposal we write. This page is its public edition.

Can the specification change for our cluster?

Yes. Customer-specific changes are written into your proposal as numbered deviations, so you can see every point where your cluster differs from the baseline.

Are the GPU nodes air cooled or liquid cooled?

HGX B300 nodes are air cooled, on the OEM's recommendation at cluster scale. We ask our facilities for a path to direct-to-chip liquid cooling for GB300 NVL72 and later systems.

Which storage can we choose?

A vendor-managed appliance from VAST Data, WEKA or DDN with at least 1 TB usable per GPU, or storage nodes for your own storage software with at least 3 TB raw per GPU and a minimum of 9 nodes.

Can we bring our own IP addresses and ASN?

Yes. The edge can advertise your own prefixes and your ASN, honors your RPKI ROAs and uses BGP session authentication.

Does the specification cover GPUs other than the HGX B300?

No, it covers HGX B300 servers and clusters. For other GPU servers, your written proposal sets out the configuration.

Tell us what you need to run.

Share the hardware, the number of servers, the term and the start date. You receive a written proposal built on our delivery specification.