Dedicated GPU servers for AI inference

Whole NVIDIA servers with no hypervisor and no other tenant, sized by the memory your model and its KV cache need: 48 GB, 96 GB or 270 GB per GPU.

1Legion rents GPU servers for AI inference as whole machines: eight NVIDIA GPUs that serve only your traffic, with no hypervisor between your serving stack and the hardware. You choose a server by memory per GPU, because the weights and the KV cache of every live request have to fit on it.

Dedicated inference servers keep latency predictable

On a dedicated server, the only requests competing for GPU memory and memory bandwidth are your own.

For a dense model, generating each token reads all of its weights from GPU memory, so memory bandwidth sets decode speed. A 70B-parameter model in FP8 is 70 GB of weights, and an HGX B300 GPU reads its memory at 7.7 TB/s, which puts the ceiling for a single sequence near 110 tokens per second before KV cache reads. Batching serves many sequences from the same read. On shared hardware, another tenant's load moves that ceiling. On ours there is one tenant and no hypervisor, and changes on our side follow written change management with at least 7 days' notice of high-risk maintenance. Our article on why LLM inference breaks on shared GPU infrastructure covers the mechanisms.

LLM inference hardware sized by weights and KV cache

The memory you need is the model's weights plus the KV cache of every concurrent sequence, plus headroom for activations and the runtime.

270 GB HBM3e per GPU on HGX B300
96 GB GDDR7 per GPU on RTX PRO 6000 Blackwell
48 GB GDDR6 per GPU on L40S

Weights take 2 bytes per parameter in FP16 or BF16, 1 byte in FP8 and half a byte in FP4, so a 70B-parameter model needs 140 GB, 70 GB or 35 GB. The KV cache grows with every token in flight: a Llama 3 70B-class model with 80 layers and 8 KV heads stores about 0.33 MB per token at 16-bit precision, or about 10.7 GB for one 32,768-token sequence.

70B model in FP8, one GPUMemory left after weightsConcurrent 8K sequencesConcurrent 32K sequences
HGX B300, 270 GBabout 200 GBabout 74about 18
RTX PRO 6000 Blackwell, 96 GBabout 26 GBabout 9about 2

These are upper bounds. They ignore activations and framework overhead and assume a 16-bit KV cache, and quantizing the cache stretches them. The arithmetic is worked through in what is left for the KV cache at 96 and 270 GB.

Which server fits which model

HGX B300 serves the largest models and longest contexts, RTX PRO 6000 Blackwell serves 70B-class models in FP8 or FP4, and L40S serves smaller models.

HGX B300

270 GB of HBM3e per GPU at 7.7 TB/s, and 2.1 TB per server. A 405B-parameter model in FP4, about 203 GB, fits on one GPU with about 67 GB left for the cache. Allocation open, in Toronto.

HGX B300 servers

RTX PRO 6000 Blackwell

96 GB of GDDR7 with ECC per GPU and 768 GB per server, with FP8 and FP4 on fifth-generation Tensor Cores. A 70B model in FP4 leaves about 61 GB per GPU for the cache. Allocation open, in Montreal.

RTX PRO 6000 servers

L40S

48 GB of GDDR6 with ECC per GPU at 864 GB/s, 384 GB per server, and 733 TFLOPS of dense FP8. An 8B-parameter model in FP16 takes 16 GB and leaves about 32 GB for the cache. On request.

L40S servers

When one model needs more memory than a server holds, GB300 NVL72 puts 72 GPUs and 20 TB of HBM3e in one NVLink domain with 130 TB/s of NVLink bandwidth, by reservation.

One replica per GPU, eight per server

An 8-GPU server is eight separate memory pools, so most deployments run one model replica per GPU behind a load balancer.

On HGX B300 that can be eight replicas of a 70B model in FP8, each holding about 18 sequences of 32K tokens, or four two-GPU replicas of a 405B model in FP8 over NVLink at 1.8 TB/s per GPU. RTX PRO 6000 Blackwell GPUs connect over PCIe 5.0 x16 rather than NVLink, so per-GPU replicas suit them: eight 70B replicas in FP4, or four GPUs serving while four fine-tune the next version. Their memory bandwidth is roughly a fifth of a B300 GPU's, so they fit batched serving better than the lowest single-stream latency. For small models, MIG splits one RTX PRO 6000 into up to four 24 GB instances and one B300 GPU into up to seven. Our articles on what fits on a B300 node and what fits on an RTX PRO 6000 node give the layouts.

Serving public traffic from the edge

On HGX B300 clusters built to our delivery specification, the edge network is designed for public inference endpoints.

  • Two independent transit providers at 100 Gb/s per circuit, on physically diverse paths, with eBGP and BFD.
  • Dedicated public service addresses, typically eight, with your VIPs advertised over BGP, failover within 5 seconds and IPv6 dual stack.
  • Volumetric layer 3 and 4 DDoS scrubbing of at least 1 Tb/s, activated through BGP within 5 minutes.
  • A redundant NAT pair with at least 10 million concurrent sessions and dedicated SNAT addresses.
  • Your own IP space and ASN, with RPKI ROAs honored.

The full design is on storage and networking, and serving on B300 is covered in B300 for production inference.

Where inference servers run

HGX B300 runs in Toronto, and RTX PRO 6000 Blackwell and other inference servers run in Montreal.

Toronto

Canada

In service

NVIDIA HGX B300 servers and clusters.

Montreal

Canada

In service

RTX PRO 6000 Blackwell and other inference servers, with onsite engineering support.

Delaware

United States

Coming online

HGX B300 capacity for customers who need their compute in the United States.

Helsinki

Finland

In development

A brownfield data center site in development for future capacity in Europe.

Partner network: 49 data centers in 26 cities across North America, Europe, Africa and Australia. See every location

HGX B300 capacity in Delaware, in the United States, is coming online. If your data has to stay in Canada, choose Toronto or Montreal; see our data centers and GPU cloud in Canada.

How renting inference servers works

Inference servers are rented whole for 36, 48 or 60 months at one fixed monthly rate set in a written proposal, with no egress fees on the traffic your endpoints send.

You pay a down payment at signing, then monthly over the term, and longer terms carry lower rates. How to buy explains the onboarding forms and the contract.

Questions buyers ask

Can we rent a single GPU for inference?

No. We rent whole servers with eight GPUs each. One model replica per GPU, or MIG instances, let you run several models on one server.

Which server fits a 70B model?

RTX PRO 6000 Blackwell holds a 70B model in FP8 or FP4 on one 96 GB GPU. For long contexts or high concurrency, HGX B300 leaves about 200 GB per GPU for the KV cache after FP8 weights.

Do you charge per token, per request or for egress?

No. You pay one fixed monthly rate for the servers over the term, and there are no egress fees.

Can we benchmark our model before we sign?

We do not offer trials or proofs of concept. Our engineers size the server with you from your model's weights, context length and concurrency, and every cluster is burned in before handover, with the results in an acceptance report.

Where are your inference servers?

HGX B300 servers are in Toronto, and RTX PRO 6000 Blackwell and other inference servers are in Montreal. HGX B300 capacity in Delaware, in the United States, is coming online.

Which serving software can we run?

The servers are bare metal, so you install your own stack, for example vLLM, SGLang or TensorRT-LLM. We can also install and run managed Kubernetes underneath it.

Size an inference server for your model

Tell us the model, the precision, the context length and the traffic you expect, and we reply with a written proposal.